Results 41 to 50 of about 311,227 (259)

Appropriate methods to analyse power conversion harmonics [PDF]

open access: yes, 2013
Nowadays, non-linear loads represent the majority of the residential electrical consumers. The limits on emission and immunity are imposed by IEC- standards, however there is a lack in the domain 2 – 150 kHz.
Desmet, Jan   +2 more
core   +2 more sources

The circuit parameters measurement of the SABALAN-I plasma focus facility and comparison with Lee Model

open access: yesResults in Physics, 2017
The circuit parameters are investigated in a Mather-type plasma focus device. The experiments are performed in the SABALAN-I plasma focus facility (2 kJ, 20 kV, 10 µF). A 12-turn Rogowski coil is built and used to measure the time derivative of discharge
F.S. Karimi   +4 more
doaj   +1 more source

High-Bandwidth Combinational Rogowski Coil for SiC MOSFET Power Module

open access: yesIEEE transactions on power electronics, 2022
Existing current sensors suffer from insufficient measurement bandwidth or large insertion area to faithfully capture the continuous switching transient current of wide-bandgap devices.
Wen Zhang   +4 more
semanticscholar   +1 more source

Research on current detection system of underground intelligent substatio

open access: yesGong-kuang zidonghua, 2018
In view of problems of traditional current detection method which took electromagnetic current transformer as the core that it was difficult to install and maintain, took up a lot of space and has low precision, a current detection system of underground ...
CHEN Lianyu, GAO Qing
doaj   +1 more source

Design of Open-Ended Structure Wideband PCB Rogowski Coil Based on New Winding Method

open access: yesElectronics, 2022
Compared with the traditional Rogowski coil, printed circuit board (PCB) Rogowski coil has the advantages of high measurement accuracy, simple manufacturing process and low cost. It has become an important device in current measurement.
Qin Tan   +5 more
semanticscholar   +1 more source

METHODS AND INSTRUMENTS FOR NONCONTACT DIAGNOSTICS OF THE TCAS SYSTEM

open access: yesАвіаційно-космічна техніка та технологія, 2018
This article is devoted to an investigation of the TCAS (Traffic Collision Avoidance System) diagnostics and self-diagnostics problems. The aim of the current research is to prepare the TCAS system built-in diagnostics aid and to build a model of a ...
Islam Asad Isgandarov   +2 more
doaj   +1 more source

Hybrid Sensing of Internal and Surface Partial Discharges in Air-Insulated Medium Voltage Switchgear

open access: yesEnergies, 2020
Partial discharge (PD) measurements have proved their reliability for health monitoring of insulation systems in power system components including synchronous generators, power transformers, switchgear and cables etc.
Ghulam Amjad Hussain   +4 more
doaj   +1 more source

Low‐frequency performance of openable flexible double‐loop Rogowski coil

open access: yesIET Science, Measurement & Technology, 2021
Double‐loop Rogowski coils have become increasingly popular in the market because of their high sensitivity and flexible usage compared to their extended single‐loop coils. Due to the high number of turns (thousands) and its small turn diameter (
Xiaoyu Liu, Hui Huang, Chaoqun Jiao
doaj   +1 more source

Evaluation of Flexible Rogowski Coil Performances In Power Frequency Applications

open access: yes, 2011
This paper investigates the effects of some influence quantities on the measurement of power frequency sinusoidal currents by means of flexible Rogowski coil sensors.
Chiampi, Mario   +2 more
core   +1 more source

Modeling and Analyzing the Mutual Inductance of Rogowski Coils of Arbitrary Skeleton

open access: yesSensors, 2019
There are Rogowski coils of various shapes in the on-site measurement, and it is difficult to calculate the electrical quantities of Rogowski coils of curved skeleton and circular cross-section by simulation software.
Xiaoyu Liu, Hui Huang, Chaoqun Jiao
doaj   +1 more source

Home - About - Disclaimer - Privacy