Results 71 to 80 of about 504,766 (218)
Purpose Linear accelerator (LINAC)‐based single‐isocenter multi‐target (SIMT) treatment has streamlined the cranial stereotactic radiosurgery (SRS) workflow. Though efficient, SIMT delivery adds additional challenges that should be considered, including increased sensitivity to rotational errors for off‐isocenter targets.
Yohan A. Walter+4 more
wiley +1 more source
Abstract Purpose To investigate the feasibility of adapting a commercial prostate biopsy system for transrectal ultrasound (TRUS)‐guided hybrid gynecological (GYN) high‐dose‐rate (HDR) brachytherapy (BT). Leveraging 3D‐TRUS and MR image fusion, the prototype system aims to improve real‐time needle placement accuracy.
Lindsey H. Bloom+8 more
wiley +1 more source
Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White+5 more
wiley +1 more source
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood+5 more
wiley +1 more source
Abstract The establishment of guidelines and curriculum standards for medical physics residency training is a critical component of setting expectations and competencies for the profession. Since the last publication of these standards, residency training has become integrated into the eligibility criteria for most medical physics certification bodies.
Jonathon A. Nye+16 more
wiley +1 more source
Quantitative quality control of 3D water tank using image analysis
Abstract Background and objective Accurate beam data acquisition using three‐dimensional (3D) water tanks is essential for beam commissioning and quality control (QC) in clinical radiation therapy. This study introduces a novel method for quantitative QC of the system, utilizing MV images and webcam videos.
Yuki Tanimoto+9 more
wiley +1 more source
Localization accuracy of 6‐second CBCT for lung IGRT with various breathing patterns
Abstract Purpose The 6‐second cone beam computed tomography (CBCT) acquisition of the Ethos HyperSight (Varian Medical Systems, Inc. Palo Alto, CA, USA) on‐board imaging system offers benefits, but could be too fast to accurately capture an average target position in a free‐breathing lung cancer patient. This study aimed to ascertain whether a 6‐second
Jihye Koo+5 more
wiley +1 more source
Abstract Purpose Histotripsy is a focal tumor therapy that utilizes focused ultrasound (US) to mechanically destroy tissue. To overcome visualization limitations of diagnostic US‐guidance, C‐arm cone beam CT (CBCT)‐guided histotripsy is being developed, for which a mobile C‐arm could increase accessibility. CBCT‐guided histotripsy uses a phantom with a
Grace M. Minesinger+5 more
wiley +1 more source
Cortical Excitability Before and After Long‐Term Perampanel Treatment for Epilepsy
ABSTRACT Objective Antiseizure medications (ASMs), which may influence cortical excitability, are the mainstay of epilepsy treatment. Transcranial magnetic stimulation (TMS) helps evaluate cortical excitability. We assessed changes in TMS responses using serial TMS measurements in people treated with an adjunctive noncompetitive AMPA‐receptor ...
Robert M. Helling+6 more
wiley +1 more source
The cost as a function of the number of experiments for a non‐symmetric 21×21$$ 21\times 21 $$ system. Four approaches are shown: the proposed stochastic conjugate gradient ILC (SCGILC) method (), deterministic conjugate gradient ILC (), stochastic gradient descent ILC () and deterministic gradient descent ILC ().
Leontine Aarnoudse, Tom Oomen
wiley +1 more source