Results 111 to 120 of about 218,129 (345)

UR‐cycleGAN: Denoising full‐body low‐dose PET images using cycle‐consistent Generative Adversarial Networks

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley   +1 more source

Spectral Evolution of Two High-Energy Gamma-Ray Bursts

open access: yes, 2004
The prompt emission of the gamma-ray bursts is found to be very energetic, releasing ~10^51 ergs in a flash. However, their emission mechanism remains unclear and understanding their spectra is a key to determining the emission mechanism.
Briggs, M. S.   +4 more
core   +1 more source

Beam model development and clinical experience with RadCalc for treatment plan quality assurance in online adaptive workflow with an MR‐linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen   +3 more
wiley   +1 more source

The Effect of Coherent Structures on Stochastic Acceleration in MHD Turbulence

open access: yes, 2005
We investigate the influence of coherent structures on particle acceleration in the strongly turbulent solar corona. By randomizing the Fourier phases of a pseudo-spectral simulation of isotropic MHD turbulence (Re $\sim 300$), and tracing collisionless ...
Achterberg A.   +14 more
core   +2 more sources

Localization accuracy of 6‐second CBCT for lung IGRT with various breathing patterns

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The 6‐second cone beam computed tomography (CBCT) acquisition of the Ethos HyperSight (Varian Medical Systems, Inc. Palo Alto, CA, USA) on‐board imaging system offers benefits, but could be too fast to accurately capture an average target position in a free‐breathing lung cancer patient. This study aimed to ascertain whether a 6‐second
Jihye Koo   +5 more
wiley   +1 more source

Stochastic modeling of ground acceleration for eastern Cuba and the city of Santiago de Cuba

open access: yesMinería y Geología, 2023
The southeastern region of Cuba is the most seismically dangerous area of the country because of its close location to the border of the Caribbean plate with the North American plate.
Bladimir Moreno-Toiran   +2 more
doaj  

Full Band Spectra Analysis of Gait Acceleration Signals for Peripheral Arterial Disease Patients

open access: yesFrontiers in Physiology, 2018
Peripheral arterial disease (PAD) is an artherosclerotic occlusive disorder of distal arteries, which can give rise to the intermittent claudication (IC) phenomenon, i.e., limb pain and necessity to stop.
Mihaela I. Chidean   +7 more
doaj   +1 more source

Acceleration-induced spectral beats in strongly driven harmonic oscillators [PDF]

open access: green, 2023
P. V. Santos   +2 more
openalex   +1 more source

Home - About - Disclaimer - Privacy