Results 71 to 80 of about 165,880 (282)

Polarization‐resolved femtosecond Vis/IR spectroscopy tailored for resolving weak signals in biological samples using minimal sample volume

open access: yesFEBS Open Bio, EarlyView.
Unique biological samples, such as site‐specific mutant proteins, are available only in limited quantities. Here, we present a polarization‐resolved transient infrared spectroscopy setup with referencing to improve signal‐to‐noise tailored towards tracing small signals. We provide an overview of characterizing the excitation conditions for polarization‐
Clark Zahn, Karsten Heyne
wiley   +1 more source

i-PHAOS: An Overview with an Open-Source Collaborative Database on Miniaturized Integrated Spectrometers

open access: yesSensors
On-chip spectrometers are increasingly becoming tools that might help in everyday life needs. The possibility offered by several available integration technologies and materials to be used to miniaturize spectrometers has led to a plethora of very ...
Carla Maria Coppola   +3 more
doaj   +1 more source

Multi‐omics and low‐input proteomics profiling reveals dynamic regulation driving pluripotency initiation in early mouse embryos

open access: yesFEBS Open Bio, EarlyView.
Mouse pre‐implantation development involves a transition from totipotency to pluripotency. Integrating transcriptomics, epigenetic profiling, low‐input proteomics and functional assays, we show that eight‐cell embryos retain residual totipotency features, whereas cytoskeletal remodeling regulated by the ubiquitin‐proteasome system drives progression ...
Wanqiong Li   +8 more
wiley   +1 more source

High-resolution wide-band Fast Fourier Transform spectrometers

open access: yes, 2012
We describe the performance of our latest generations of sensitive wide-band high-resolution digital Fast Fourier Transform Spectrometer (FFTS). Their design, optimized for a wide range of radio astronomical applications, is presented.
A. Bell   +11 more
core   +1 more source

Meta‐analysis fails to show any correlation between protein abundance and ubiquitination changes

open access: yesFEBS Open Bio, EarlyView.
We analyzed over 50 published proteomics datasets to explore the relationship between protein levels and ubiquitination changes across multiple experimental conditions and biological systems. Although ubiquitination is often associated with protein degradation, our analysis shows that changes in ubiquitination do not globally correlate with changes in ...
Nerea Osinalde   +3 more
wiley   +1 more source

A Review of the Emerging Field of Underwater Mass Spectrometry

open access: yesFrontiers in Marine Science, 2016
Mass spectrometers are versatile sensor systems, owing to their high sensitivity and ability to simultaneously measure multiple chemical species. Over the last two decades, traditional laboratory-based membrane inlet mass spectrometers have been adapted
Emily Chua   +4 more
doaj   +1 more source

Ultrastable reference pulser for high-resolution spectrometers [PDF]

open access: yes, 1970
Solid-state double-pulse generator for a high resolution semiconductor detector meets specific requirements for resolution /0.05 percent/, amplitude range /0.1-13 MeV/, and repetition rate /0.1-1000 pulses per second/.
Brenner, R.   +3 more
core   +1 more source

Erythropoietin modulates hepatic inflammation, glucose homeostasis, and soluble epoxide hydrolase and epoxides in high‐fat diet‐induced obese mice

open access: yesFEBS Open Bio, EarlyView.
Erythropoietin administration suppresses hepatic soluble epoxide hydrolase (sEH) expression, leading to increased CYP‐derived epoxides. This is associated with a shift in hepatic macrophage polarization characterized by reduced M1 markers and increased M2 markers, along with reduced hepatic inflammation, suppressed hepatic lipogenesis, and attenuated ...
Takeshi Goda   +12 more
wiley   +1 more source

Etalon Array Reconstructive Spectrometry. [PDF]

open access: yes, 2017
Compact spectrometers are crucial in areas where size and weight may need to be minimized. These types of spectrometers often contain no moving parts, which makes for an instrument that can be highly durable. With the recent proliferation in low-cost and
Huang, Eric, Liu, Zhaowei, Ma, Qian
core   +2 more sources

Discovery and Targeted Proteomic Studies Reveal Striatal Markers Validated for Huntington's Disease

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Clinical trials for Huntington's disease (HD) enrolling persons before clinical motor diagnosis (CMD) lack validated biomarkers. This study aimed to conduct an unbiased discovery analysis and a targeted examination of proteomic biomarkers scrutinized by clinical validation. Methods Cerebrospinal fluid was obtained from PREDICT‐HD and
Daniel Chelsky   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy