Results 91 to 100 of about 7,210,108 (295)
High mass accuracy analytical applications of Fourier transform ion cyclotron resonance mass spectrometry [PDF]
The performance capabilities of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry are higher than any other type of mass spectrometer, making this technique suitable for a range of analytical applications.
Wills, Rebecca Helen
core
Investigation of Electrochemical Solid-Liquid Interfaces Using In Situ Liquid Time-of-flight Secondary Ion Mass Spectrometry [PDF]
Electrochemical interfaces are the core of various important fields, such as energy conversion and storage, biochemistry, sensors, and corrosion. The investigations of the structure-performance relationship of electrochemical solid-liquid interfaces have
ZHANG Yan-yan1, WANG Fu-yi1,2,3
doaj +1 more source
Fully additive vertical organic electrochemical transistors (vOECTs) with channel‐length of 226 nm on a 50 µm compostable substrate achieve >106 current modulation and ∼36 mS transconductance. Ion‐selective integration enables 1.1 mA dec−1 sensitivity and 36 µm detection limit, highlighting a scalable platform for sustainable electronics and ...
Giulia Frusconi +3 more
wiley +1 more source
Microscope imaging by time-of-flight secondary ion mass spectrometry
The concept of Secondary Ion Microscopy, introduced by Castaing et al. [1], is applied to a direct imaging time-of-flight (TOF) mass spectrometer. The ion optical configuration for a particular [2] stigmatic imaging TOF mass spectrometer is reviewed.
Bruno W. Schueler
core +1 more source
The increasing use of nanoparticles (NP) in commercial products requires elaborated techniques to detect NP in the tissue of exposed organisms. However, due to the low amount of material, the detection and exact localization of NP within tissue sections ...
Lothar Veith +8 more
doaj +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source
Conformational Switching of Proteins on Material Surfaces Enabled by Peptide‐Oriented Adsorption
Responsive biointerfaces could be achieved using conformationally responsive proteins; however, their interconversion can be lost upon surface adsorption. Herein, we demonstrate that the incorporation a Au binding peptide into calmodulin allows for binding control on Au wherein the protein retains conformational switching. This capability was confirmed
Sakthirupini Ramamurthy +7 more
wiley +1 more source
Memristive‐Gated RC‐Delay Synaptic Transistors for Time‐Encoded Analog in‐Memory Computing
A Memristive‐Gated Transistor for Time‐Encoded Analog In‐Memory Computing — By exploiting the RC delay of a self‐rectifying interface‐type memristor, nonlinear I–V distortion is structurally bypassed, enabling 3‐bit nonvolatile memory, spike‐timing‐based analog encoding, and hardware‐calibrated reservoir‐computing validation within a unified device ...
Yun‐Seo Shin +7 more
wiley +1 more source
Advanced methods in fourier transform ion cyclotron resonance mass spectrometry [PDF]
Mass spectrometry (MS) is a powerful analytical technique used to characterize various compounds by measuring the mass-to-charge ratio (m/z). Among different types of mass analyzers, Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR ...
Qi, Yulin
core
Simulation and Engineering Design of a Secondary Quadrupole Ion Transmission System
In this study, the secondary quadrupole ion transmission system was investigated, focusing on its design and optimization using computational fluid dynamics (CFD) and ion optics simulations.
Xin ZHANG +8 more
doaj +1 more source

