Results 71 to 80 of about 164,512 (299)

Study on the Analysis of Uranium-in Rat Hair by Secondary Ion Mass Spectrometry

open access: yesJournal of Isotopes, 2021
Hair samples, as a non-invasive biological material, it is gradually gaining attention in the fields of nuclear forensics, environmental monitoring, occupational exposure detection, and medicine due to its certain accumulation effect on human trace ...
HU Ruixuan;SHEN Yan;LI Lili;HUANG Shenghui;ZHAO Lifei;ZHAO Yonggang
doaj  

Cyclic azapeptide CD36 ligand attenuates cardiac injury and reduces long‐chain fatty acid accumulation after myocardial ischemia–reperfusion in mice

open access: yesFEBS Open Bio, EarlyView.
In a murine model of myocardial ischemia and reperfusion (MI/R), the CD36 azapeptide ligand MPE‐298 reduces cardiac injury and transiently lowers left ventricular long‐chain fatty acids (LCFAs) accumulation 3 h after reperfusion, accompanied by a decrease of oxidative stress and inflammation‐associated genes' expression in the heart and adipose tissue.
Jade Gauvin   +12 more
wiley   +1 more source

Secondary Ion Mass Spectrometry [PDF]

open access: yes, 2020
Kaija Schaepe   +5 more
  +4 more sources

UiO‐66 metal–organic frameworks in biomedicine: From structural tunability to bioimaging, photodiagnostics, and photodynamic cancer therapy

open access: yesFEBS Open Bio, EarlyView.
UiO‐66(Zr) metal–organic frameworks are chemically stable, biocompatible, and highly tunable nanomaterials. Their modular structure enables controlled drug delivery, multimodal bioimaging, and light‐activated photodynamic therapy, supporting integrated diagnostic and therapeutic (theranostic) applications in cancer and biomedical research.
Veronika Huntošová   +2 more
wiley   +1 more source

Analysis of bone minerals by time-of-flight secondary ion mass spectrometry: a comparative study using monoatomic and cluster ions sources. [PDF]

open access: yes, 2007
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is an important tool for the analysis of bone minerals at implant surfaces. Most studies have been performed with monoatomic primary ion sources such as Ga(+) with poor secondary molecular ion ...
Per Malmberg   +14 more
core   +1 more source

Polyelectrolytes as new matrices for secondary ion mass spectrometry [PDF]

open access: yesJournal of the American Society for Mass Spectrometry, 2005
Significant enhancements in ion yields in time-of-flight secondary ion mass spectrometry (TOF-SIMS) are observed when water-soluble analytes are mixed with a polyelectrolyte, e.g., poly(diallyldimethylammonium chloride) or poly(sodium 4-styrenesulfonate), and then deposited in the layer-by-layer method on a surface. This previously unobserved effect is
Yit-Yian Lua   +11 more
openaire   +2 more sources

Molecular characterization of covRS mutations in M1UK Streptococcus pyogenes

open access: yesFEBS Open Bio, EarlyView.
Group A Streptococcus (GAS) acquires covRS mutations driving a hypervirulent bacterial state, frequently associated with invasive disease‐like necrotizing fasciitis. We demonstrate that the newly emerged M1UK GAS lineage can also acquire these mutations.
Jarrad Pritchard   +12 more
wiley   +1 more source

Secondary ion mass spectrometry: a tool for identification of matrix-isolated species [PDF]

open access: yesJournal of the Chemical Society, Chemical Communications, 1978
An argon matrix-isolated propane sample (1:150, 10 K) is used to demonstrate the applicability of secondary ion mass spectral analysis to the characterization of matrix-isolated species.
Jonkman, Harry T., Michl, Josef
openaire   +2 more sources

Importin 7 mediates the nuclear import of HIV‐1 integrase via a specific interacting interface

open access: yesFEBS Open Bio, EarlyView.
HIV‐1 integrase enables viral DNA integration into the host genome. By binding to the core domain of the host protein Importin 7 via its C‐terminal domain, the integrase is transported across the nuclear membrane into the nucleus, where integration of the viral genome into host DNA takes place. This translocation is a critical step for subsequent viral
Juana Bana   +5 more
wiley   +1 more source

Stigmatic imaging of secondary ions in MeV-SIMS spectrometry by linear Time-of-Flight mass spectrometer and the TimePix detector [PDF]

open access: yes, 2019
Secondary ion mass spectrometry (SIMS), based on primary ions within the MeV energy domain, also known as MeV-SIMS, is a subject of increasing scientific interest.
Kelemen, Mitja   +14 more
core   +1 more source

Home - About - Disclaimer - Privacy