Results 1 to 10 of about 6,277 (213)

Investigation of LiF, Mg and Ti (TLD-100) Reproducibility [PDF]

open access: yesJournal of Biomedical Physics and Engineering, 2015
LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137.
Sadeghi M., Sina S., Faghihi R.
doaj   +3 more sources

Thermoluminescent Characteristics of GR-200, TLD-700H and TLD-100 for Low Dose Measurement: Linearity, Repeatability, Dose Rate and Photon Energy Dependence [PDF]

open access: yesJournal of Biomedical Physics and Engineering, 2022
Background: The dose values obtained from procedures of diagnostic radiology are relatively low. To accurately and precisely measure the dose values in this dose range, it is necessary to know the characteristics of dosimeters.Objective: The aim of this ...
Mojgan Alizadeh   +5 more
doaj   +2 more sources

Evaluation of LiF:Mg,Ti (TLD-100) for Intraoperative Electron Radiation Therapy Quality Assurance. [PDF]

open access: yesPLoS ONE, 2015
Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron ...
Raffaele Liuzzi   +4 more
doaj   +2 more sources

Dose–Response of TLD-100 in the Dose Range Useful for Hypofractionated Radiotherapy [PDF]

open access: yesDose-Response, 2020
Purpose: The aim of the study was to exploit the feasibility of thermoluminescent dosimeters (TLDs) in radiation therapy techniques in which high dose per fraction is involved. Methods: Dose–response of TLD-100 (LiF: Mg, Ti) was investigated in both 6-MV
Raffaele Liuzzi   +6 more
doaj   +2 more sources

A novel targeted lung denervation multi-polar radiofrequency ablation system for moderate to severe COPD patients: a translational study [PDF]

open access: yesRespiratory Research
Background Disruption of parasympathetic pulmonary nerves, which release acetylcholine and trigger airway smooth muscle constriction, has been shown to improve lung function and alleviate symptoms in patients with chronic obstructive pulmonary disease ...
Rui Xu   +11 more
doaj   +2 more sources

Head and Neck Immobilization Masks: Increase in Dose Surface Evaluated by EBT3, TLD‐100 and PBC Method

open access: yesPrecision Radiation Oncology, 2020
Positioning and immobilization tools are considered essential components of radiotherapy treatments to guarantee that the planned dose distribution can be efficiently reached.
Arnie Verde Nolasco   +1 more
doaj   +3 more sources

Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. [PDF]

open access: yesPLoS ONE, 2013
This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma
Guerda Massillon-J L   +4 more
doaj   +2 more sources

A Photo-transfer Thermoluminescence (PTTL) Study of TLD-100 over a Wide Dose Range

open access: yesSüleyman Demirel Üniversitesi Fen-Edebiyat Fakültesi Fen Dergisi, 2023
Photo-transferred thermoluminescence (PTTL) is defined as the transfer of electrons from deep traps into shallow traps via optical stimulation. The importance of PTTL is that it allows for a second measurement of dose assessments for accuracy in cases ...
Engin Aşlar
doaj   +1 more source

Investigation of Thermal Quenching Effect for Lithium Fluoride (LiF) Type Dosimeters

open access: yesCumhuriyet Science Journal, 2023
Thermal quenching is described as a decrease in luminescence efficiency with increasing measurement temperature. Luminescence intensity decreases with increasing heating rates in the presence of thermal quenching.
Engin Aşlar
doaj   +1 more source

Measurement of Entrance Skin Dose and the Dose Received by Different Organs in Panoramic Dental Imaging [PDF]

open access: yesJournal of Biomedical Physics and Engineering, 2020
Background: Thermoluminescence dosimetry(TLD) has been known as one of the most effective methods for dose estimation in diagnostic radiology. Orthopantomogram (OPG) imaging is used by many dentists, oral and maxillofacial surgeons as an effective tool ...
A Ahmadi   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy