Measurement of Entrance Skin Dose and the Dose Received by Different Organs in Panoramic Dental Imaging [PDF]
Background: Thermoluminescence dosimetry(TLD) has been known as one of the most effective methods for dose estimation in diagnostic radiology. Orthopantomogram (OPG) imaging is used by many dentists, oral and maxillofacial surgeons as an effective tool ...
A Ahmadi +3 more
doaj +1 more source
The Performance of LiF:Mg-Ti for Proton Dosimetry within the Framework of the MoVe IT Project
Proton therapy represents a technologically advanced method for delivery of radiation treatments to tumors. The determination of the biological effectiveness is one of the objectives of the MoVe IT (Modeling and Verification for Ion Beam Treatment ...
Vittoria D’Avino +4 more
doaj +1 more source
The production of thermoluminescence (TL) dosimeters fabricated from B2O3-CaF2-Al2O3-SiO2 doped with Cu and Pr for use in diagnostic radiology is the main goal of this research.
Ibrahim Algain +3 more
doaj +1 more source
Research on the effectiveness of panoramic room walls has been carried out in the Radiology Installation of Prof. Dr. MA Hanafiah SM Batusangkar. This study aims to determine the effectiveness of the panoramic room walls in absorbing radiation emitted by
Dila Nelvo Dasril, Nerifa Dewilza
doaj +1 more source
Telah dilakukan kalibrasi TLD-100 di udara menggunakan radiasi sinar-X pada rentang Radiation Qualities in Radiodiagnostic (RQR). Kalibrasi dilakukan untuk mengetahui koefisien kalibrasi TLD di udara, faktor koreksi kualitas radiasi dan pengaruh variasi ...
Nisaul Chaira Yeni +2 more
doaj +1 more source
CALIBRAÇÃO DE DOSÍMETROS TERMOLUMINESCENTES (TLD-100) PARA UTILIZAÇÃO EM DOSIMETRIA AMBIENTAL
Detectores de radiação são instrumentos que, quando posicionados em um meio onde há radiação, são capazes de indicar a sua presença. Detectores termoluminescentes, são materiais que, após serem submetidos a um campo de radiação ionizante, tornam-se ...
SABRINA DONATO DA SILVA +4 more
doaj +1 more source
PEMETAAN LAJU DOSIS RADIASI MENGGUNAKAN TLD-100 DI PABRIK SEMEN
Telah dilakukan pemetaan laju dosis radiasi di pabrik semen dengan sumber radiasi buatan (Sinar-X) dan alam. Pemetaan laju dosis radiasi masing-masing dilakukan di tiga tempat, yaitu pada radiasi buatan (Sinar-X) pemetaan dilakukan di ruangan CCR, On ...
Alwis Abbas
doaj +1 more source
Does Electron Spectrum Affect TLD-100 Dose Response in 6 MV Photon Beam Irradiation?
In this study, the electron spectrum effect on the TLD-100 dosimeter response to a 6 MV photon beam in different media like water, aluminum, polystyrene, iron, copper, and lead using Monte Carlo and Burlin cavity theory was evaluated.
Neslihan Sarıgül
doaj +1 more source
Application of Thermoluminescence Dosimeter TLD-100 to Measure Thermal Neutron Fluence by LiF Activation Method [PDF]
: In this study, TL signal induced after activation of 6Li present in TlD-100 was applied in order to measure the thermal neutron fluence in the Tehran Research Reactor Core (TRRC).
F Torkzadeh +2 more
doaj
This work examined the thermoluminescence dosimetry characteristics of Ag-doped ZnO thin films. The hydrothermal method was employed to synthesize Ag-doped ZnO thin films with variant molarity of Ag (0, 0.5, 1.0, 3.0, and 5.0 mol%).
Hammam Abdurabu Thabit +5 more
doaj +1 more source