Results 61 to 70 of about 425,748 (301)

ABL kinase‐dependent phosphorylation of SH proteins promotes their direct interaction with CRK family SH2 domains

open access: yesFEBS Letters, EarlyView.
CT10 regulator of kinase (CRK) and CRK‐Like (CRKL) are signaling adaptors driving cell adhesion, motility, differentiation, and proliferation. SH2‐domain containing (SH) proteins are enriched in YXXP motifs which when phosphorylated create preferred binding sites for CRK family SH2 domains.
Phoebe M. Cousens   +8 more
wiley   +1 more source

A line selection method of mine leakage protectio

open access: yesGong-kuang zidonghua, 2020
Aiming at problem of low accuracy of line selection when single-phase grounding fault occurs in mine power supply system at present, according to characteristics of obvious difference of zero-sequence current waveform between fault line and non-fault ...
YU Qun, SHANG Xueli
doaj   +1 more source

TRAIL‐PEG‐Apt‐PLGA nanosystem as an aptamer‐targeted drug delivery system potential for triple‐negative breast cancer therapy using in vivo mouse model

open access: yesMolecular Oncology, EarlyView.
Aptamers are used both therapeutically and as targeting agents in cancer treatment. We developed an aptamer‐targeted PLGA–TRAIL nanosystem that exhibited superior therapeutic efficacy in NOD/SCID breast cancer models. This nanosystem represents a novel biotechnological drug candidate for suppressing resistance development in breast cancer.
Gulen Melike Demirbolat   +8 more
wiley   +1 more source

Analysis of Mine Low-voltage Leakage Protection in Situation of Great Disparity between Long and Short Lines and Big Unbalanced Current

open access: yesGong-kuang zidonghua, 2010
The paper explained that traditional leakage protection principles such as zero-sequence direction relay principle and zero-sequence current's maximum principle are unable to implement selective leakage protection in situation of great disparity between ...
SU Po, CHEN Qing
doaj   +2 more sources

Non-Directional Earth Fault Passage Indication in Isolated Neutral Distribution Networks

open access: yesEnergies, 2020
In this paper, two new methods for locating single-phase to ground faults in isolated neutral distribution networks are proposed. The methods are based on the analysis of symmetrical sequence currents.
Amir Farughian   +2 more
doaj   +1 more source

Wavelet Based Induction Motor Fault Diagnosis Using Zero Sequence Current

open access: yes, 2017
Induction motor stator fault is diagnosed by applying Discrete Wavelet transform on zero sequence components. The single phasing stator fault is created and diagnosed in the induction motor model developed in stationary reference frame, under varying ...
W Abitha Memala, V Rajini
core   +1 more source

Operational constraints of zero-sequence current feeding in bearingless PM synchronous machines

open access: yes, 2021
For magnetically levitated drives with a 3-phase stator winding, one degree of freedom in the rotor motion can be controlled through a zero-sequence current. For example, an axial active magnetic bearing or a single-phase motor winding can be fed by this
Dietz, Daniel, Binder, Andreas
core   +1 more source

Network divergence analysis identifies adaptive gene modules and two orthogonal vulnerability axes in pancreatic cancer

open access: yesMolecular Oncology, EarlyView.
Tumors contain diverse cellular states whose behavior is shaped by context‐dependent gene coordination. By comparing gene–gene relationships across biological contexts, we identify adaptive transcriptional modules that reorganize into distinct vulnerability axes.
Brian Nelson   +9 more
wiley   +1 more source

Rules to estimate the expected values of zero-sequence impedances in 3 phase core-type transformers [PDF]

open access: yes, 2018
Simple rules to estimate the expected values of zero-sequence impedance measurements for 3-phase core-type transformers are shown. The proposed rules are based on the analysis of magnetic circuits.
Burgos Díaz, Juan Carlos   +1 more
core   +1 more source

Analysis on Circulating Current and Split Capacitor Voltage Balance for Modular Multilevel Converter Based Three-phase Four-wire Split Capacitor DSTATCOM

open access: yesJournal of Modern Power Systems and Clean Energy, 2021
We propose a modular multilevel converter (MMC) based three-phase four-wire (3P4W) split capacitor distribution static synchronous compensator (DSTATCOM), aiming at compensating unbalanced and reactive load currents.
Lei Lin, Jialu He, Chen Xu
doaj   +1 more source

Home - About - Disclaimer - Privacy