Results 31 to 40 of about 2,580,794 (302)

Effect of Multi-Joint Clearance Coupling on Shimmy of Nose Landing Gear

open access: yesAerospace, 2023
The existence of joint clearances in the nose landing gear (NLG) is inevitable and significantly affects shimmy. It was found that the interaction of each joint clearance is closely related to the analysis of shimmy stability.
Guang Feng, Bingyan Jiang, Yiyao Jiang
doaj   +1 more source

Sensitivity Analysis for Optimal Design of Multibody Systems with Clearance Joint [PDF]

open access: yesInternational Journal of Advanced Design and Manufacturing Technology, 2018
This paper deals with the sensitivity analysis and optimization of system parameters for a classical slider-crank mechanism as a multibody system which includes a clearance between the joints of coupler and slider. Due to the nonlinearity involved in the
Saeed Ebrahimi   +2 more
doaj  

Research on Influence of Joint Clearance on Precision of 3-TPT Parallel Robot [PDF]

open access: yesMechanical Sciences, 2019
The error model of the working accuracy of parallel mechanism was established in this paper. The D-H matrix method and error independent method were used to analyze the clearance error of mechanism joint based on the inverse position kinematics solution.
C. Zhu, Z. Zhao
doaj   +1 more source

Research on High Precision Stiffness Modeling Method of Redundant Over-Constrained Parallel Mechanism

open access: yesSensors, 2023
Traditional stiffness modeling methods do not consider all factors comprehensively, and the modeling methods are not unified, lacking a global stiffness model.
Sen Wang   +5 more
doaj   +1 more source

An Adaptive Dissipation–Precision Coordinated Multi-Scale Implicit Integration Algorithm for Thermo-Mechanical Coupled Dynamics of Flexible Multibody Systems with Temperature-Dependent Clearance Joints

open access: yesApplied Sciences
Extreme orbital thermal cycling and temperature-dependent clearance nonlinearity make it difficult to predict contact–impact, stick–slip, and bifurcation responses of flexible deployable space structures with sufficient stability, accuracy, and ...
Yuntao Hua   +5 more
doaj   +1 more source

Wear prediction for dry revolute joint with clearance in multibody system by integrating dynamics model and wear model

open access: yesLatin American Journal of Solids and Structures
This work presents an investigation on wear prediction of multibody system including dry revolute clearance joint using a computational methodology. A procedure to analyze multibody system in which wear is present at revolute joints is presented.
Z.F. Bai, H.B. Zhang, Y. Sun
doaj   +1 more source

Motion Accuracy and Dynamic Responses of Dual-Manipulator on Spacecraft Considering Clearance Joints

open access: yesAerospace
Clearance in joints caused by assemblage, manufacturing errors, and wear is inevitable, which will affect the dynamic performance of the dual-manipulator system on spacecraft.
Yiling Kuang, Zhengfeng Bai, Cheng Wei
doaj   +1 more source

Nonlinear Characteristics of Revolute Joints with Clearance

open access: yesJournal of Aerospace Technology and Management, 2013
http://dx.doi.org/10.5028/jatm.v5i3.236 The nonlinear contact characteristic of revolute joint with clearance can degrade the performance of deployable structure. In this article, tensile and compressive tests are adopted to investigate the accuracies of the simplest conformal model and nonconformal model for contact, which are used to calculate the ...
Rong-qiang, Liu   +3 more
openaire   +5 more sources

Guidelines for Pediatric Radiotherapy Simulation: A Report From the Children's Oncology Group Radiation Oncology Discipline

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Pediatric radiation therapy presents unique challenges compared to adult treatments, including those of immobilization, potential need for sedation, and the critical importance of accurate, reproducible positioning. Additionally, heightened attention to imaging doses is necessary to minimize long‐term toxicity in survivors.
Parham Alaei   +17 more
wiley   +1 more source

POLYCENTRIC EXOPROSTHETIC KNEE JOINTS – EXTENT OF SHORTENING DURING SWING PHASE

open access: yesCanadian Prosthetics & Orthotics Journal, 2020
BACKGROUND: An often assumed advantage of polycentric knee joints compared to monocentric ones is the improved ground clearance during swing phase due to the geometric shortening of the lower leg segment (LLS).
Thomas Maximilian Köhler   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy