Results 191 to 200 of about 255,657 (229)
Some of the next articles are maybe not open access.
Ultrastructural and confocal laser scanning microscopic examination of TUNEL‐positive cells
The Journal of Pathology, 1997TdT-mediated dUTP-biotin nick end labelling (TUNEL) has been widely used for detecting cells with DNA fragmentation or apoptotic cells. However, since the concept of apoptosis is based on cellular ultrastructure, it is important to identify the morphological features of TUNEL-positive cells.
K, Kimura +9 more
openaire +2 more sources
Opto-mechanical analysis for confocal laser scanning microscopes
SPIE Proceedings, 2005The confocal imaging has become one of the most widely applied microscopic techniques in various fields, such as biotechnology, automation engineering, optical engineering, solid-state physics, metallurgy, integrated circuit inspection, etc. Confocal laser scanning microscopy (CLSM) is primarily based on the use of apertures in the detection path to ...
Gao-Wei Chang +4 more
openaire +1 more source
GFP fluorescence imaging with laser confocal scanning microscope
SPIE Proceedings, 1999ABSTRACT With gene marking technique, green fluorescent protein (GFP) and nodule bacteria gene has been linked together toform a single fusion gene expression vector. Then the vector is transferred into the nodule bacteria and the astragalus sinicusis invaded by the vector.
Yanhua Yu +3 more
openaire +1 more source
Scanning and detection techniques used in a confocal scanning laser microscope
Journal of Microscopy, 1990SUMMARYA two‐mirror scanning mechanism for confocal microscopy is described. No optical components, in addition to the scanning mirrors, are used. Design criteria and performance of the scanner are discussed. The photometric linearity of a detector unit incorporating a photomultiplier tube is reported, and a dual detector unit with tunable split ...
openaire +1 more source
Fiber-optic laser scanning confocal microscope suitable for fluorescence imaging.
Applied Optics, 1994P. Delaney, M. Harris, R. King
semanticscholar +1 more source
Lateral Resolution Test for Confocal Laser Scanning Microscope
Key Engineering Materials, 2014To meet the performance test for the confocal laser scanning microscope (CLSM) accurately in some specific application occasions, the spatial resolution imaging principle of confocal laser scanning microscope was analyzed theoretically. And the micron line spacing as the measurement standard has tried to investigate the lateral resolution of CLSM in ...
openaire +1 more source
Fluorescence lifetime measurements using a novel fiber‐optic laser scanning confocal microscope
, 1992K. Ghiggino, M. Harris, P. Spizzirri
semanticscholar +1 more source
Optic fibre bundle contact imaging probe employing a laser scanning confocal microscope
Journal of Microscopy, 2002Vladimir Dubaj +3 more
semanticscholar +1 more source

