The surgical point of view about persistent air leaks: prevention first [PDF]
No abstract ...
Anile, Marco +4 more
core +1 more source
ENDOVASCULAR TREATMENT FOR DISORDERS OF THE VENOUS SYSTEM
The annual rate of deep vein thrombosis in general population is from 5 to 9 cases per 10 000, whereas for venous thromboembolism (deep vein thrombosis and pulmonary embolism taken together) amounts to 14 cases per 10 000.
A. G. Osiev +2 more
doaj +1 more source
A Brief Review on Failed Hybrid Treatment for Massive Pulmonary Embolism: Catheter-Directed Thrombolysis (CDT) and Pharmaco-Mechanical Thrombolysis (PMT). [PDF]
Cueto-Robledo G +7 more
europepmc +1 more source
Recent advances in intra-arterial thrombolysis
Thrombolytic therapy has revolutionized acute ischemic stroke (AIS) treatment; however it is clear that intravenous (IV) thrombolytic therapy has certain limitations, including a short-time window for use, poor specificity for the site of arterial ...
Bershad Eric, Suarez Jose
doaj
Revolution in acute ischaemic stroke care: a practical guide to mechanical thrombectomy [PDF]
Rapid, safe and effective arterial recanalisation to restore blood flow and improve functional outcome remains the primary goal of hyperacute ischaemic stroke management.
Cowley, P +3 more
core +1 more source
ABSTRACT Circadian rhythms orchestrate cardiovascular physiology by regulating immune and inflammatory pathways. Disruption of these rhythms profoundly alters vascular homeostasis, thereby promoting the onset and progression of cardiovascular diseases (CVD).
Tian Zhang +22 more
wiley +1 more source
Tissue plasminogen activator-based clot busting: Controlled delivery approaches. [PDF]
Cardiovascular diseases are the leading cause of death worldwide. Thrombosis, the formation of blood clot (thrombus) in the circulatory system obstructing the blood flow, is one of the main causes behind various ischemic arterial syndromes such as ...
El-Sherbiny, IM, Elkholi, IE, Yacoub, MH
core +1 more source
We systematically summarize how each scale dictates fundamental choices in design feature, manufacturing technology, driving mechanism, and control strategy, which are inherently governed by scale‐dominated physical principles. Furthermore, the application of scale‐determined operation modes of microrobots across different stages of medical ...
Hang Yin +3 more
wiley +1 more source
Can pulsed ultrasound increase tissue damage during ischemia? A study of the effects of ultrasound on infarcted and non-infarcted myocardium in anesthetized pigs [PDF]
Background The same mechanisms by which ultrasound enhances thrombolysis are described in connection with non-beneficial effects of ultrasound. The present safety study was therefore designed to explore effects of beneficial ultrasound characteristics on
Göran K Olivecrona +54 more
core +1 more source
Activatable smart contrast agents for photoacoustic imaging
This review highlights recent advances in smart activatable photoacoustic imaging (PAI) contrast agents, which dynamically modulate their optical properties in response to external stimuli or microenvironmental cues. It discusses their molecular design, activation mechanisms, biomedical applications, and future prospects for clinically tailored use ...
Donghyeon Oh +5 more
wiley +1 more source

