Optimal Dispatch of Residential Photovoltaic Inverters Under Forecasting Uncertainties

open access: yes, 2014
Efforts to ensure reliable operation of existing low-voltage distribution systems with high photovoltaic (PV) generation have focused on the possibility of inverters providing ancillary services such as active power curtailment and reactive power ...
Dall'Anese, Emiliano   +3 more
core   +1 more source

Standardized Elemental Composition Analysis of Graphene‐Related 2D Materials (GR2M) With SEM/EDS and XPS Works Reliably

open access: yesSmall, Volume 22, Issue 25, 4 May 2026.
The elemental composition of a series of laboratory graphene oxide and reduced graphene oxide materials and a commercial graphene oxide material of high quality is analyzed with the standardless SEM/EDS quantification. XPS is used as a reference method.
Paul Mrkwitschka   +7 more
wiley   +1 more source

Neutral zone closing overvoltage characteristics analysis in traction power supply system for group trains

open access: yes电力工程技术
During the operation of group trains, the trains frequently pass through the neutral zone. Then, the generated closing overvoltage will cause serious insulation damage to the traction power supply system and the trains′ high-voltage equipment box.
XIANG Nianwen   +5 more
doaj   +1 more source

Mechanism and suppression of breaking overvoltage of DC circuit breakers

open access: yesHigh Voltage
The occurrence of breaking overvoltage in a DC circuit breaker (DCCB) poses a potential threat to the safe operation of a DC grid. Based on the structure of the ±10 kV three‐terminal DC distribution network, this paper sets up the medium‐voltage DCCB and
Lu Qu   +7 more
doaj   +1 more source

Coordinated preventive control strategy for transient overvoltage suppression in hybrid AC/DC sending-side systems

open access: yesInternational Journal of Electrical Power & Energy Systems
As a predominant issue within line-commutated converters-based high voltage direct current (DC) transmission systems, commutation failure may trigger transient overvoltage problems and the tripping of large-scale renewable generation sets in hybrid AC/DC
Boyu Qin   +4 more
doaj   +1 more source

Influence of overvoltage waves on the development of partial discharges [PDF]

open access: diamond, 2023
A V Korzhov   +4 more
openalex   +1 more source

A database ATP simulated waveforms of shunt reactor switching cases with vacuum breakers on motor circuits [PDF]

open access: yes, 2009
This paper presents a database ATP (Alternative Transient Program) simulated waveforms for shunt reactor switching cases with vacuum breakers in motor circuits following interruption of the starting current.
Kam, Shui-cheong, Ledwich, Gerard
core   +1 more source

Study on the Influence of Grounding Resistance on Cable Fault Overvoltage

open access: yesEnergies
The cable grounding connecting method and grounding resistance have a significant influence on the cable fault overvoltage. This paper considers a 500 kV long cable project in Beijing as the research object; a model was implemented in ATP-EMTP, and ...
Baotong Song   +4 more
doaj   +1 more source

The 8.4-GHz low-noise maser pump source assembly [PDF]

open access: yes
Improved pump source assemblies and new 8.4-GHz low noise traveling-wave masers (TWMs) were installed at the same time at Deep Space Stations 14 and 43 as part of the Mark IVA DSCC Antenna Microwave Subsystems upgrade. The pump source assemblies are part
Cardenas, R.
core   +1 more source