Results 11 to 20 of about 75,526 (309)
Partial Discharges Monitoring for Electric Machines Diagnosis: A Review
Online monitoring of Partial Discharges (PDs) in rotating electrical machines is an useful tool for machine prognosis, as it presents reduced costs compared to intrusive inspections and is associated with relevant problems.
Jonathan dos Santos Cruz +6 more
semanticscholar +1 more source
Research of partial discharge characteristics features in bushings [PDF]
The paper is devoted to partial discharge measurement and analysis in switchgear bushings. PD bushing structure analysis is described to assess possible defect sources in bushings.
D. A. Polyakov +2 more
doaj +1 more source
Investigation characteristics of partial discharges in artificial defects of power transmission lines [PDF]
The article describes the study of the characteristics of partial discharges (PD) in various types of artificial defects in cable lines. A total of 13 types of insulation defects are considered.
D. A. Polyakov +4 more
doaj +1 more source
Partial Discharges Classification Methods in XLPE Cable: A Review
Partial discharge (PD) signal classification analysis on cross-linked polyethylene (XLPE) cables is complex, requiring a comprehensive understanding of the characteristics of PD patterns.
N. Rosle +3 more
semanticscholar +1 more source
Partial Discharge (PD) is one of the symptoms of an electrical insulation problem, and its permanence can lead to the complete deterioration of the electrical insulation in high-voltage equipment such as power transformers.
Hamidreza Besharatifard +4 more
semanticscholar +1 more source
In this article, it is provided a comprehensive survey on the most relevant research in the area of detection, classification and location of partial discharge (PD) sources using the radiometric or ultra high frequency (UHF) method, focusing mainly on ...
G. V. Xavier +5 more
semanticscholar +1 more source
Analysis of partial discharges in supporting insulators [PDF]
The diagnostics of overhead power lines is an important issue in the modern electric power industry. Sometimes supporting insulators are destroyed by external factors.
D. A. Polyakov +4 more
doaj +1 more source
This paper investigates partial discharge (PD) characteristics that lead to the erosion of silicone rubber (SR) polymer under AC stress and DC stress of both polarities.
Valeria Pevtsov +2 more
doaj +1 more source
In this study, a methodology for automatic recognition of multiple simultaneous types of partial discharges (PDs) in hydro-generator stator windings was proposed.
Ramon C. F. Araújo +2 more
doaj +1 more source
Partial discharges in power transformers [PDF]
Tansformers are among the most responsible and expensive elements of the power system, therefore monitoring the technical condition of the transformer is an important and urgent task.
Lopatchenko Gleb +4 more
doaj +1 more source

