Results 11 to 20 of about 3,088,305 (335)
Partial discharges (PDs) are one of the most important classes of ageing processes that occur within electrical insulation. PD detection is a standardized technique to qualify the state of the insulation in electric assets such as machines and power ...
Jorge Alfredo Ardila-Rey +6 more
doaj +2 more sources
Identifying harmonic attributes from online partial discharge data [PDF]
Partial discharge (PD) monitoring is a key method of tracking fault progression and degradation of insulation systems. Recent research discovered that the harmonic regime experienced by the plant also affects the PD pattern, questioning the conclusions ...
Rowland, S.M. +4 more
core +4 more sources
Partial Discharges Monitoring for Electric Machines Diagnosis: A Review
Online monitoring of Partial Discharges (PDs) in rotating electrical machines is an useful tool for machine prognosis, as it presents reduced costs compared to intrusive inspections and is associated with relevant problems.
Jonathan dos Santos Cruz +6 more
semanticscholar +1 more source
Partial Discharge (PD) is one of the symptoms of an electrical insulation problem, and its permanence can lead to the complete deterioration of the electrical insulation in high-voltage equipment such as power transformers.
Hamidreza Besharatifard +4 more
semanticscholar +1 more source
Investigation of Partial Discharges in AlN Substrates Under Fast Transient Voltages
The objective of this article is to characterize partial discharge (PD) inception voltages and patterns at sinusoidal and square voltages in insulating ceramic substrates with generic manufacturing defects. PD tests were conducted on active metal brazed (
I. Semenov +4 more
semanticscholar +1 more source
Partial Discharges Classification Methods in XLPE Cable: A Review
Partial discharge (PD) signal classification analysis on cross-linked polyethylene (XLPE) cables is complex, requiring a comprehensive understanding of the characteristics of PD patterns.
N. Rosle +3 more
semanticscholar +1 more source
Partial Discharge Behaviour within Two Spherical Cavities in a Dielectric Material [PDF]
In high voltage insulation systems, a typical defect that exists is a void cavity. It is known that voids are a common source of partial discharge (PD) activity within an insulation system.
Illias, H A, Lewin, P L, Chen, G
core +2 more sources
In this article, it is provided a comprehensive survey on the most relevant research in the area of detection, classification and location of partial discharge (PD) sources using the radiometric or ultra high frequency (UHF) method, focusing mainly on ...
G. V. R. Xavier +5 more
semanticscholar +1 more source
A frequency-based RF partial discharge detector for low-power wireless sensing [PDF]
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems ...
Baker, P.C. +2 more
core +4 more sources
Interpretation of wavelet analysis and its application in partial discharge detection. [PDF]
The objective of the paper is to discuss a tool which is proving extremely efficient in partial discharge measurement studies. Though the technique itself is not new, its application to partial discharge studies is.
Zhou, C., Kemp, I. J., Ma, X.
core +5 more sources