Results 21 to 30 of about 3,088,305 (335)
Measurement of Partial Discharge Activities within Two Artificial Spherical Voids in an Epoxy Resin [PDF]
Measurement of partial discharge activities within insulation systems has been extensively performed. It has been widely used in the performance assessment of an insulation system and for insulation diagnostics.
Illias, H A, Lewin, P L, Chen, G
core +2 more sources
Partial discharges in power transformers [PDF]
Tansformers are among the most responsible and expensive elements of the power system, therefore monitoring the technical condition of the transformer is an important and urgent task.
Lopatchenko Gleb +4 more
doaj +1 more source
In high voltage insulation systems, dielectric materials may be exposed to partial discharges (PD), which can lead to equipment failures and safety hazards.
Michał Kozioł +3 more
doaj +1 more source
Research of partial discharge characteristics features in bushings [PDF]
The paper is devoted to partial discharge measurement and analysis in switchgear bushings. PD bushing structure analysis is described to assess possible defect sources in bushings.
D. A. Polyakov +2 more
doaj +1 more source
In this paper, a novel image denoising algorithm and novel input features are proposed. The algorithm is applied to phase-resolved partial discharge (PRPD) diagrams with a single dominant partial discharge (PD) source, preparing them for automatic ...
Ramon C. F. Araújo +3 more
doaj +1 more source
Locating Partial Discharges in Power Transformers with Convolutional Iterative Filtering
The most common source of transformer failure is in the insulation, and the most prevalent warning signal for insulation weakness is partial discharge (PD).
Jonathan Wang +3 more
doaj +1 more source
Partial discharge. Part XXIV: The analysis of PD in HVDC equipment
High voltage dc is required in a wide range of consumer, commercial, and military applications. Presently available PD analysis for dc systems can extend far beyond the old-fashioned "not more than 'n' PD pulses per minute over a given magnitude".
Morshuis, P. (author) +2 more
openaire +3 more sources
Epoxy resin is one of the most common polymers used as part of the insulation system in key electrical assets such as power transformers and hydrogenerators.
J. M. Rodríguez-Serna +3 more
semanticscholar +1 more source
Electrical trees are defects originated and driven by partial discharges (PD) activity and this is the reason why their modelling and simulation are fundamental for the ageing mechanisms comprehension and diagnosis analyses of insulation systems compound
Johnatan M. Rodríguez‐Serna +1 more
doaj +1 more source
A partial discharge (PD) measuring system has been deployed in order to identify and measure PD in a high voltage (HV) cable joint under impulse and superimposed voltages under laboratory conditions.
Jia-Yang Wu +3 more
semanticscholar +1 more source

