The paper provides a new method for determining the dimensions and position of defects in the insulation of the stator windings of turbogenerators when partial discharges (PD) are measured in them.
A. M. Baboraik +3 more
doaj +1 more source
Feature extraction and ageing state recognition using partial discharges in cables under HVDC
PD detection is an effective way to evaluate the degradation state of cable insulation. The extraction and selection of relevant features from PD raw data have been mostly investigated to recognize the types of insulation defects in HV equipment. In this
Nathalie Morette, T. Ditchi, Y. Oussar
semanticscholar +1 more source
Partial discharge (PD) is an electrical discharge within a dielectric which does not bridge the electrodes. PD measurement has been widely used for assessing performance of insulation systems.
Lewin, P L, Illias, H, Chen, G
core +2 more sources
Partial discharges measurement by UHF method [PDF]
The unconventional UHF (Ultra High Frequency) method of measuring partial discharges (PD) is based on measuring electromagnetic waves (EM) in the UHF frequency band (300-3000) MHz, using appropriate antennas.
Malešević Nevena +3 more
doaj
Continuous online monitoring of partial discharges in high voltage cables
This paper reviews data acquisition, transmission and processing methodologies for continuous online monitoring of partial discharges in power cable systems.
Tian, Y. +9 more
core +1 more source
Partial discharge (PD) monitoring is one of the most used tools for diagnosing the condition of electrical equipment and machines that operate normally at high voltage levels.
J. Ardila-Rey +5 more
semanticscholar +1 more source
THE PURPOSE. Development of diagnostic methods for high-voltage insulators in operation based on continuous recording of electromagnetic radiation. Hardware and software implementation of the device based on this technique.
T. G. Galieva +4 more
doaj +1 more source
It is well assessed that partial discharges, PD, are one of the major causes of MV and HV cable system breakdown, thus investigating partial discharge phenomenology and harmfulness is a key topic in relation to electric asset component reliability ...
Gian Carlo Montanari +2 more
doaj +1 more source
Analysis of partial discharges in supporting insulators [PDF]
The diagnostics of overhead power lines is an important issue in the modern electric power industry. Sometimes supporting insulators are destroyed by external factors.
D. A. Polyakov +4 more
doaj +1 more source
Medium-voltage (MV) cables often experience a shortened lifespan attributed to insulation breakdown resulting from accelerated aging and anomalous operational and environmental stresses.
H. Kumar +3 more
semanticscholar +1 more source