Modeling of Current Transformers Under Saturation Conditions [PDF]
During a short circuit the input signal of the relay can be distort by the magnetic core saturation of the current transformer. It is useful to verify the behavior of CT by a mathematical model. The paper describes one phase and three phase models and it
Martin Prochazka
doaj +3 more sources
Numerical methodology to evaluate unipolar saturation current limit of DC corona discharge in complex geometries [PDF]
The unipolar saturation current limit ( $${I}_{sat}$$ I sat ) gives an upper limit to the corona current that can be obtained from a unipolar corona discharge.
Sangwoo Kim, Jungho Hwang
doaj +2 more sources
FPGA-Based Smart Sensor to Detect Current Transformer Saturation during Inrush Current Measurement [PDF]
Current transformer saturation affects measurement accuracy and, consequently, protection reliability. One important concern in the case of overcurrent protections is the discrimination between faults and inrush current in power transformers.
G. de J. Martínez-Figueroa +2 more
doaj +2 more sources
Current Transformer Saturation Detection Method Based on Artificial Neural Network [PDF]
When current transformer is saturated, mainly due to the presence of an exponentially decaying DC component in the fault current, its secondary current has a distinctive distorted waveform which significantly differs from its primary (true) waveform.
Yu. V. Rumiantsev
doaj +4 more sources
Fast Detection of Current Transformer Saturation Using Stacked Denoising Autoencoders
Malfunctions in relay protection devices are predominantly caused by current transformer (CT) saturation which produces distortion in current measurements and disturbances in power system protection.
Sopheap Key +3 more
doaj +2 more sources
Detection of Current Transformer Saturation Based on Machine Learning [PDF]
One of the tasks in the operation of electric power systems is the correct functioning of the protection system and emergency automation algorithms. Instrument voltage and current transformers, operating in accordance with the laws of electromagnetism ...
Ismoil Odinaev +5 more
doaj +2 more sources
Digital Current Measurement Element for Operation During Current Transformer Severe Saturation
The development and implementation of a digital current measurement element for proper operation during current transformer (CT) magnetic core severe saturation are considered.
Yu. V. Rumiantsev +3 more
doaj +3 more sources
Influence of Current Transformer Saturation on Operation of Current Protection
An analysis of the influence of instrument current transformer errors on operation of current protection of power supply diagram elements has been carried out in the paper.
F. A. Romaniouk +5 more
doaj +1 more source
Design and test of a magnetic saturation-type fault current limiter
Fault current limiter (FCL) is an effective technique for the fault isolation and protection in the direct current (DC) grid. In this study, a magnetic saturation-type FCL is designed and tested. Firstly, its basic principle is introduced.
Lu Qu, Rong Zeng, Zhanqing Yu, Ge Li
doaj +2 more sources
The study on the Mal-operation of the transformer current differential protection during external faults cause by CT saturation [PDF]
This paper analyses the unusual mal-operation of the differential protection for transformer current differential protection during the external fault. The mal-operation reason is researched in detail, based on the mathematical analysis, the simulation ...
Wu Jianhong +5 more
doaj +1 more source