Results 11 to 20 of about 147,033 (306)

Research of characteristics of transient pulse in coal mine resonant grounding system

open access: yesGong-kuang zidonghua, 2014
By means of deduction of zero-sequence current expressions when single-phase grounding fault occurs in single substation mode and multi-substation mode of coal mine resonant grounding system, polarity relationship between transient pulse of fault line ...
WANG Jinhong
doaj   +1 more source

Combined line selection of single-phase grounding faults considering harmonic injection of distributed powers

open access: yes电力工程技术, 2023
With the improvement of the requirements for the safe operation of distribution network lines, the harmonics injected by distributed power generation make the existing line selection methods ineffective, and the fault line selection method with a single ...
LI Yan   +4 more
doaj   +1 more source

Faulty Feeder Detection Method Based on VMD–FFT and Pearson Correlation Coefficient of Non-Power Frequency Component in Resonant Grounded Systems

open access: yesEnergies, 2020
Through analyzing the transient components and transient characteristics in transient zero-sequence current (TZSC), a novel fault feeder detection method based on the transient correlation of non-power frequency components (NPFCs) for the resonant ...
Kewen Wei   +4 more
doaj   +1 more source

Transient fault area location and fault classification for distribution systems based on wavelet transform and Adaptive Neuro-Fuzzy Inference System (ANFIS) [PDF]

open access: yes, 2018
A novel method to locate the zone of transient faults and to classify the fault type in Power Distribution Systems using wavelet transforms and Adaptive Neuro-Fuzzy Inference Systems (ANFIS) has been developed.
Ghazizadeh-Ahsaee, Mahdi   +3 more
core   +2 more sources

Transient Fault Detection and Location in Power Distribution Network: A Review of Current Practices and Challenges in Malaysia

open access: yesEnergies, 2021
An auto-restoration tool to minimize the impact of faults is one of the critical requirements in a power distribution system. A fault-monitoring system is needed for practical remote supervision to identify faults and reduce their impacts, and thus ...
Saidatul Habsah Asman   +3 more
doaj   +1 more source

Fault-tolerant sub-lithographic design with rollback recovery [PDF]

open access: yes, 2008
Shrinking feature sizes and energy levels coupled with high clock rates and decreasing node capacitance lead us into a regime where transient errors in logic cannot be ignored.
DeHon, André, Naeimi, Helia
core   +2 more sources

Fault Feeder Identification in Non-effectively Grounded Distribution Network with Secondary Earth Fault

open access: yesJournal of Modern Power Systems and Clean Energy, 2021
Secondary earth faults occur frequently in power distribution networks under harsh weather conditions. Owing to its characteristics, a secondary earth fault is typically hidden within the transient of the first fault.
Shu Zhang   +3 more
doaj   +1 more source

Line selection method with transient state based on intrinsic mode energy

open access: yesGong-kuang zidonghua, 2013
In view of problem that fault line selection method based on wavelet analysis of coal mine power grid ca't guarantee the optimal decomposition effect due to the decomposition effect depends on choice of primary function, the paper presented a fault line ...
WANG Qing-liang   +4 more
doaj   +1 more source

Research on automatic location of single-phase leakage fault zone in coal mine power network

open access: yesGong-kuang zidonghua, 2021
The necessity of automatic single-phase leakage fault zone location is analyzed in this paper from two aspects, namely, the need for leakage detection and the value of leakage fault zone location.
GAO Hongjie1   +2 more
doaj   +1 more source

FAUST: fault-injection script-based tool [PDF]

open access: yes, 2003
The tool described in this paper aims at evaluating the effectiveness of software-implemented fault-tolerant techniques used in safety-critical systems. The target application is stressed with the injection of transient or permanent faults.
Benso, Alfredo   +5 more
core   +1 more source