Results 31 to 40 of about 10,323 (170)

Underground power supply system grounding fault section positioning method based on wide-area current transient component

open access: yesGong-kuang zidonghua, 2022
At present, most of the research on underground power supply system grounding fault positioning in coal mine adopts the transient method, which needs to collect zero sequence voltage and zero sequence current of the line at the same time.
OUYANG Min   +10 more
doaj   +1 more source

Research of Fault Line Selection Method of Distribution Network Based on Transient Zero-sequence Energy

open access: yesGong-kuang zidonghua, 2012
For problem of ineffectiveness of traditional line selection methods by use of single feature value caused by complex and random fault borderline, small steady component of fault and reverse phase of instantaneous zero-sequence power when single-phase ...
TIAN Shu, HE Jin-peng, NIE He
doaj  

Rolling Bearing Fault Feature Extraction Based on Adaptive Tunable Q-Factor Wavelet Transform and Spectral Kurtosis

open access: yesShock and Vibration, 2020
The fault feature of the rolling bearing is difficult to extract when weak fault occurs and interference exists. The tunable Q-factor wavelet transform (TQWT) can effectively extract the weak fault characteristic of the rolling bearing, but the manual ...
Jianlong Zhao   +2 more
doaj   +1 more source

Field experiment using transient energy method to locate a single-phase to ground fault

open access: yesGlobal Energy Interconnection, 2020
Distribution networks in China and several other countries are predominantly neutral inefficiently grounding systems (NIGSs), and more than 80% of the faults in distribution networks are single-phase-to-ground (SPG) faults.
Wei Xie   +6 more
doaj   +1 more source

NBTI-Aware Transient Fault Rate Analysis Method for Logic Circuit Based on Probability Voltage Transfer Characteristics

open access: yesAlgorithms, 2016
The reliability of Very Large Scale Integration (VLSI) circuits has become increasingly susceptible to transient faults induced by environmental noise with the scaling of technology.
Zhiming Yang   +3 more
doaj   +1 more source

A low-cost testing for transient faults

open access: yesUbiquity, 2006
Unconventional and low - cost software implemented testing technique for processor transient faults are briefly discussed here. On-line signatures of the Processor Status Register have been used here for detecting transient faults.
openaire   +1 more source

Multilevel Feature Extraction Method for Adaptive Fault Diagnosis of Railway Axle Box Bearing

open access: yesShock and Vibration, 2023
Railway axle box bearing fault signal contains high Q-factor resonance and low Q-factor transient shock components with periodic transient shock features that can characterize bearing faults. However, extracting fault features is usually difficult due to
Zhigang Liu, Long Zhang, Guoliang Xiong
doaj   +1 more source

Transient Fault Detection in Networked Control Systems [PDF]

open access: yesInternational Journal of Distributed Sensor Networks, 2014
Transient faults appear unpredictablly and frequently in networked control systems (NCSs), which directly affect the safety of system. However, they can not be accurately identified due to various kinds of causes, so the detection of them needs more systematic and comprehensive system knowledge.
Xiong-Feng Huang   +4 more
openaire   +2 more sources

Single Terminal Transient Protection Scheme Based on Fuzzy Multi-criteria Fusion

open access: yesZhongguo dianli
The existing single-terminal transient protection schemes rely solely on single fault feature for fault identification, which leads to the poor identification reliability. This paper thus proposes a novel single-terminal transient protection scheme based
Meiling LUO   +5 more
doaj   +1 more source

Transient energy protection based on wavelet packet transform for hybrid bipolar HVDC transmission system

open access: yesIET Generation, Transmission & Distribution, 2021
In hybrid bipolar DC transmission systems with different types of converters at each pole, the transient high‐frequency component of the voltage signal under a single‐pole grounding fault and an inter‐pole fault is significantly different for internal ...