Results 11 to 20 of about 13,098 (275)

Performance Enhancement of MRAC via Generalized Dynamic Inversion

open access: yesActuators
Model Reference Adaptive Control (MRAC) guarantees closed loop stability and desired steady state performance of dynamical systems without undue dependence upon their mathematical models. However, the applicability of MRAC may not be suitable for systems
Alharith Mahmoud, Abdulrahman H. Bajodah
doaj   +2 more sources

Adaptive VS-MRAC for disturbance cancellation [PDF]

open access: yesElectronics Letters, 1995
A variable structure, model reference adaptive control (VS-MRAC) devoted to cancel interferences without the requirement of an auxiliary input is proposed. This method is an improved alternative to the strategies recently proposed in the control theory literature.
Bertran Albertí, Eduardo   +1 more
openaire   +6 more sources

Performance Improvement of Various MRAC Setups Based on LLM

open access: goldIEEE Access
This study proposes integrating Large Language Models (LLMs) into the adaptation mechanism of Model Reference Adaptive Control (MRAC) systems to improve their performance.
Handan Gursoy-Demir   +4 more
doaj   +2 more sources

Controlador adaptativo MRAC em um pêndulo amortecido baseado em modelos matemáticos determinísticos

open access: diamondRevista Principia, 2021
Os sistemas de controle automático têm grande importância no progresso da Engenharia e da Tecnologia. O controle adaptativo tem a capacidade de modificar seus parâmetros, quando necessário, para diminuir o erro do sistema.
Brunna Santana de Vasconcellos   +3 more
doaj   +2 more sources

Robust model reference adaptive controller for 3-DOF planar manipulator [PDF]

open access: yesScientific Reports
The three-link robotic manipulator plays an important role in industrial automation, where productivity and efficiency are directly related to precise motion control.
Tofik Kemal Mohammed   +1 more
doaj   +2 more sources

COMPARATIVE ANALYSIS OF THE MODIFIED MRAC-MIT SYSTEM AND MRAC-LYAPUNOV SYSTEM

open access: diamondInformatika i sistemy upravleniya, 2021
The article deals with the comparative analysis of the quality of adaptive thermal object control systems with reference models using the modified MIT rule and Lyapunov rule, implemented in MATLAB-Simulink software complexes (PCs). The proposed control algorithms were tested in laboratory condi-tions and provided the required quality of transition ...
E.S. Duvanov   +5 more
openaire   +2 more sources

An automatic pipeline for PET/MRI attenuation correction validation in the brain [PDF]

open access: yesEJNMMI Physics, 2023
Purpose Challenges in PET/MRI quantitative accuracy for neurological uses arise from PET attenuation correction accuracy. We proposed and evaluated an automatic pipeline to assess the quantitative accuracy of four MRI-derived PET AC methods using ...
Mahdjoub Hamdi   +3 more
doaj   +2 more sources

Enhanced Control Strategies for Lower Limb Rehabilitation Robots: A Comparative Study of MRAC, PID-ZN, and MRAC-PSO Controllers

open access: yesApplied Bionics and Biomechanics
Wearable robots for rehabilitation have dramatically advanced the medical field regarding helping patients suffering from lower limb impairments to regain mobility and ameliorate their range of motion (ROM).
Mustapha Amine Sadi   +5 more
doaj   +2 more sources

Application of direct MRAC in PI controller for DC-DC boost converter

open access: diamondInternational Journal of Power Electronics and Drive Systems (IJPEDS), 2020
Almost all electronic components require a DC power supply at present days. The needs of DC power supplies from low voltage scales, medium voltages such as generators, to high voltage scales for high voltage electricity transmission.
L. Ardhenta, R. K. Subroto
semanticscholar   +3 more sources

Evaluating a radiotherapy deep learning synthetic CT algorithm for PET-MR attenuation correction in the pelvis [PDF]

open access: yesEJNMMI Physics
Background Positron emission tomography–magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone.
Jonathan J. Wyatt   +7 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy