Results 11 to 20 of about 1,123,144 (299)

Performance Evaluation of Analytical Methods for Parameters Extraction of Photovoltaic Generators

open access: yesEnergies, 2020
This paper presents a succinct exploration of several analytical methods for extracting the parameters of the single-diode model (SDM) of a photovoltaic (PV) module under standard test conditions (STC). The paper investigates six methods and presents the
Nader Anani, Haider Ibrahim
doaj   +1 more source

Transmission Line Distance Protection Under Current Transformer Saturation

open access: yesJournal of Modern Power Systems and Clean Energy, 2021
Conventional transmission line distance protection approaches are subject to malfunction under reverse fault-induced current transformer (CT) saturation for the typically employed breaker-and-a-half configuration.
Yuping Zheng   +5 more
doaj   +1 more source

EVALUATION OF CURRENT SIGNALS AT OBSERVED POINTS OF THE ELECTRICAL NETWORK IN PROBLEMS OF IDENTIFICATION OF CURRENT TRANSFORMER SATURATION

open access: yesВестник Северо-Кавказского федерального университета, 2022
Despite the fact that the problem of saturation of current transformers (CT) has been known for a long time, it has not lost its relevance now. Cases of malfunctioning as a result of oversaturation of CT are still recorded today.
P. Shagimardanov
doaj   +1 more source

Current Measurement Offset Error Compensation Scheme Considering Saturation of Current Controller in SPMSM Drives

open access: yesIEEE Access, 2023
A current measurement offset error compensation method for surface-mounted permanent magnet synchronous motor (SPMSM) drives that shows stable operating characteristics under the saturation of the current controller is proposed.
Sang-Il Kim   +2 more
doaj   +1 more source

A High-Precision Error Calibration Technique for Current Transformers under the Influence of DC Bias

open access: yesEnergies, 2023
A bias current in the power system will cause saturation of the measuring current transformer (CT), leading to an increase in measurement error. Therefore, in this paper, we first conducted measurements of the direct current component in a 10 kV ...
Sanlei Dang   +8 more
doaj   +1 more source

Simulation of longitudinal differential protection of transmission lines with additional stabilization and APU system [PDF]

open access: yesTehnika, 2016
This paper explains the algorithm for the longitudinal differential protection of transmission lines with automatic reclosing. Classic stabilization is not sufficient for avoiding of unnecessary operations caused by saturation of current transformer ...
Rajić Tomislav D., Stojanović Zoran N.
doaj   +1 more source

Magnetic Flux Density Feature Analysis and CT Saturation Region Recognition and Reconstruction Technology

open access: yesZhongguo dianli, 2023
To solve the problem of relay protection caused by CT saturation, a CT saturation identification method is proposed based on flux density characteristics and secondary current reconstruction technology in the distortion area.
Feng WANG   +5 more
doaj   +1 more source

Current saturation and Coulomb interactions in organic single-crystal transistors [PDF]

open access: yes, 2008
Electronic transport through rubrene single-crystal field effect transistors (FETs) is investigated experimentally in the high carrier density regime (n ~ 0.1 carrier/molecule). In this regime, we find that the current does not increase linearly with the
A F Morpurgo   +7 more
core   +6 more sources

Eddy Saturation of Equilibrated Circumpolar Currents

open access: yesJournal of Physical Oceanography, 2013
Abstract This study uses a sector configuration of an ocean general circulation model to examine the sensitivity of circumpolar transport and meridional overturning to changes in Southern Ocean wind stress and global diapycnal mixing. At eddy-permitting, and finer, resolution, the sensitivity of circumpolar transport to forcing magnitude
Munday, D, Johnson, H, Marshall, D
openaire   +2 more sources

Fast Detection of Current Transformer Saturation Using Stacked Denoising Autoencoders

open access: yesEnergies, 2023
Malfunctions in relay protection devices are predominantly caused by current transformer (CT) saturation which produces distortion in current measurements and disturbances in power system protection.
Sopheap Key   +3 more
doaj   +1 more source