Results 61 to 70 of about 6,539 (187)
Electro-optic imaging enables efficient wide-field fluorescence lifetime microscopy
Nanosecond imaging techniques, such as fluorescence lifetime imaging microscopy (FLIM), are limited by low efficiency of current detectors. Here, the authors implement an electro-optic approach using Pockels cells for wide-field image gating and ...
Adam J. Bowman +3 more
doaj +1 more source
Time-Domain Fluorescence Lifetime Imaging Techniques Suitable for Solid-State Imaging Sensor Arrays
We have successfully demonstrated video-rate CMOS single-photon avalanche diode (SPAD)-based cameras for fluorescence lifetime imaging microscopy (FLIM) by applying innovative FLIM algorithms. We also review and compare several time-domain techniques and
Robert K. Henderson +8 more
doaj +1 more source
Cyclin‐dependent kinase (CDK) 1 activity is a dynamic marker of treatment response in estrogen receptor positive breast cancer. Patient cohorts reveal CDK1 activity increases during progression to invasive disease, where high expression correlates with poor survival. Using a novel Cdk1 biosensor mouse alongside in vitro models, we demonstrate that CDK1
Sarah Alexandrou +17 more
wiley +1 more source
This work presents a multifunctional ionic liquid, [SO3H‐PMIm][OTf], that addresses A‐site cation inhomogeneity and lead toxicity in pure‐iodide wide‐bandgap perovskite solar cells. The additive enables homogeneous cation distribution, achieving 22.02% efficiency with 90% retention after 3000 h and reducing lead leakage by over 58%, thereby ...
Kai Wu +8 more
wiley +1 more source
Mechanical cues, including ECM stiffness, stretch, compression, shear stress, and traction forces, remodel trafficking across the secretory pathway, from the ER and Golgi to endolysosomal compartments and the plasma membrane. The resulting secretome reshapes ECM composition and tissue mechanics, establishing feedback loops that support homeostasis or ...
Domenico Russo +5 more
wiley +1 more source
Pinhole engineering based enhanced resolution (PEER) for fluorescence lifetime imaging microscopy
In this article, we present a differential confocal microscopy technique based on pinhole engineering that significantly enhances both lateral resolution and axial sectioning depth.
Wonsang Hwang +4 more
doaj +1 more source
A compact Phe‐Cys‐Pro‐Phe (FCPF) tag and an environment‐sensitive SBD‐Cl‐derived probe form a sequence‐selective fluorogenic pair for wash‐free live‐cell protein imaging. This minimally perturbing chemistry allows flexible insertion at termini or loops, produces strong fluorescence upon local microenvironment confinement, supports FRET‐assisted ...
Xiao Wang +11 more
wiley +1 more source
An alcohol‐adduct‐mediated strategy is employed to stabilize tin isopropoxide for the formation of a homogeneous double electron transport layer (ETL) incorporating SnO2 nanoparticles (NPs). This double‐ETL exhibits improved optical and charge‐transport properties due to reduced defect density and better energy level alignment, resulting in high ...
You‐Hyun Seo +10 more
wiley +1 more source
Measuring protein turnover in cells has been greatly assisted by fluorescent timers (FT). However, FT quantification requires relatively high fluorescence intensity samples, prohibiting their use for proteins with low or non-uniform expression like ...
Dina Dikovskaya +7 more
doaj +1 more source
Surface strain tunes the NiMo/electrolyte interface without altering intrinsic hydrogen evolution reaction (HER) kinetics. The strained surface exhibits a lower effective bubble‐detachment tendency and faster release of smaller H2 bubbles, sustaining a more accessible catalytic interface in near‐neutral electrolyte. Reduced bubble‐induced transport and
Si Eun Je +12 more
wiley +1 more source

