Results 131 to 140 of about 3,400,910 (254)
Abstract Background Carbon ion radiotherapy (CIRT) offers superior dose conformity and biological effectiveness; however, its precision is highly sensitive to respiratory motion, leading to dose uncertainty and interplay effects that compromise treatment accuracy.
Jianhua Ding, Peng Li, Chai Hong Yeong
wiley +1 more source
This study aimed to clarify the relationship between dosimetric factors and parotid gland (PG) atrophy after carbon ion radiotherapy (C-ion RT).journal ...
477990 +23 more
core
Abstract The anticipated clinical demand for carbon ion radiotherapy (CIRT) in the United States is expected to include a substantial proportion of clinically complex disease sites that require accurate, highly conformal, and adaptive treatment. These clinical needs, together with the unique physical and biological characteristics of carbon ion beams ...
Xiaoying Liang, Chris J Beltran
wiley +1 more source
Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcoma
Abstract Background Parameningeal rhabdomyosarcomas (PM‐RMS) are pediatric tumors with a high risk of local failure and severe toxicity. Intensity modulated proton therapy (IMPT) offers improved healthy tissue sparing compared to conventional photon‐based radiotherapy, and proton arc therapy (PAT) might offer further improvement in healthy tissue ...
Andreas Havsgård Handeland +6 more
wiley +1 more source
Abstract Carbon ion radiotherapy (CIRT) has evolved into an established clinical modality over the past three decades. Owing to its unique physical and biological characteristics, CIRT has demonstrated favorable outcomes for selected malignancies characterized by radioresistance, proximity to critical organs, locally advanced disease requiring safe ...
Xiaoying Liang, Chris J Beltran
wiley +1 more source
We had developed compact rotating gantry for carbon ion using superconducting magnets in 2015 which became clinically operational on 2017. The objective of this study was to assess the clinical feasibility and safety of using compact rotating gantry with
1001610 +38 more
core
Abstract Background Carbon‐ion radiotherapy exploits high linear energy transfer (LET) to enhance biological effectiveness, and low dose‐averaged LET (LETd) within the target volume is associated with local recurrence in pancreatic cancer. Although robust optimization is widely used to improve dose robustness against delivery uncertainties, systematic ...
Wisawa Phongprapun, Mutsumi Tashiro
wiley +1 more source
A pH‐switchable cerium single‐atom enzyme is developed for stage‐specific peri‐implantitis therapy. Acidic conditions trigger antibacterial peroxidase‐like activity, whereas neutral conditions activate an antioxidant superoxide dismutase ‐ and catalase ‐like enzymatic relay. This microenvironment‐adaptive catalytic strategy suppresses the IL‐6/JAK‐STAT
Xiaomin Xia +10 more
wiley +1 more source
Sati Akbaba,1–3 Kristin Lang,1,2 Thomas Held,1,2 Klaus Herfarth,1–3 Juliane Rieber,1–3 Peter Plinkert,4 Gerd U Auffarth,5 Stefan Rieken,1–3 Juergen Debus,1–3 Sebastian Adeberg1–3 1Department of Radiation Oncology ...
Akbaba S +9 more
doaj