Dosimetric response of Gafchromic™ EBT‐XD film to therapeutic protons
The EBT‐XD model of Gafchromic™ films has a broader optimal dynamic dose range, up to 40 Gy, compared with its predecessor models. This characteristic has made EBT‐XD films suitable for high‐dose applications, such as stereotactic body radiotherapy and ...
Fada Guan +11 more
doaj +1 more source
Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station [PDF]
Tissue equivalent proportional counter (TEPC) can measure the Linear Energy Transfer (LET) spectrum and calculate the equivalent dose for the complicated radiation field in space.
Uk-Won Nam +9 more
doaj +1 more source
Optimizing linear energy transfer distribution in intensity-modulated proton therapy using the alternating direction method of multipliers. [PDF]
Fan Q +8 more
europepmc +2 more sources
Modeling of a solar air collector heat transfer coefficient with regression algorithms
Solar air collectors (SAC) are thermodynamic systems that convert solar energy into useful fluid energy. SACs are very common in heating, cooling, food drying, and many other low-temperature applications.
Mehmet Daş, Ebru Kavak Akpınar
doaj +1 more source
Investigate the Equivalence of Neutrons and Protons in Single Event Effects Testing: A Geant4 Study
Neutron radiation on advanced integrated circuits (ICs) is becoming important for their reliable operation. However, a neutron test on ICs is expensive and time-consuming.
Yueh Chiang +4 more
doaj +1 more source
Calibration of TEPC for CubeSat Experiment to Measure Space Radiation [PDF]
A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation.
Uk-Won Nam +11 more
doaj +1 more source
The use of microelectronic products in outer space is possible if protection is provided against special external influencing factors, including radiation effect.
I. Yu. Lovshenko +2 more
doaj +1 more source
In the paper, the regularities of changes in electricity losses and the coefficient of its transfer to a linear active load during the discharge of a supercapacitor on the load under different conditions of interruption of discharge currents are ...
А.А. Щерба +3 more
doaj +1 more source
The Effect of Energy Loss Straggling on SEUs Induced by Low-Energy Protons in 28 nm FDSOI SRAMs
Sensitive volume thickness for silicon on insulator (SOI) devices has scaled to the point that energy loss straggling cannot be ignored within the development of the manufacturing process. In this study, irradiation experiments and Geant4 simulation were
Lujie Zhang +3 more
doaj +1 more source
Current status of high linear energy transfer irradiation [PDF]
Based on laboratory investigations, high linear energy transfer (LET) particle irradiation is capable of more efficient cell kill than that associated with conventional or low LET irradiation. The advantages of high LET irradiation include: (1) a greater ability to damage hypoxic cells; (2) a lesser ability for repair of sublethal and potentially ...
M P, Richter +3 more
openaire +2 more sources