Results 41 to 50 of about 2,488,943 (332)
Long‐Term Observations of Galactic Cosmic Ray LET Spectra in Lunar Orbit by LRO/CRaTER
The Cosmic Ray Telescope for the Effects of Radiation (CRaTER) has been orbiting the Moon since 2009 aboard the Lunar Reconnaissance Orbiter (LRO). From this vantage point, it samples the interplanetary energetic particle population outside the shielding
M. D. Looper +11 more
doaj +1 more source
Research on Prediction Method for Heavy Ion SEE Cross-section Based on Proton SEE Cross-section
With the development of space technology and semiconductor technology, more and more microelectronic devices are used in spacecraft. Heavy ions and protons are two main particles that cause single event effect (SEE) in devices.
MA Xu;HAN Jinhua;GUO Gang;CHEN Qiming;LIU Jiancheng;ZHAO Shuyong;ZHANG Zheng
doaj
Nonadiabatic robust excitation transfer assisted by an imaginary gauge field
A nonadiabatic and robust method of excitation transfer in a non-Hermitian tight-binding linear chain, assisted by an imaginary gauge field, is theoretically proposed.
Longhi, Stefano
core +1 more source
Microdosimetry test on double layer beam shaping assembly neutron beam as a boron neutron capture therapy neutron source using PHITS code [PDF]
A microdosimetry test on a double layer beam shaping assembly (DLBSA) neutron beam has been carried out using the particle and heavy ion transport code system (PHITS).
Bilalodin +5 more
doaj +1 more source
Lineal Energy of Proton in Silicon by a Microdosimetry Simulation
Single event upset, or Single Event Effect (SEE) is increasingly important as semiconductor devices are entering into nano-meter scale. The Linear Energy Transfer (LET) concept is commonly used to estimate the rate of SEE.
Yueh Chiang +4 more
doaj +1 more source
Energy Transfer Rate in Double-Layer Graphene Systems: Linear Regime
We investigate theoretically the energy transfer phenomenon in a double-layer graphene (DLG) system in which two layers are coupled due to the Coulomb interlayer interaction without appreciable interlayer tunneling.
B. Bahrami +58 more
core +1 more source
Accurate characterization of radiation quality is essential for assessing radiobiological effects in radiotherapy, yet remains a major challenge. As modern treatment strategies increasingly consider not only absorbed dose but also linear energy transfer (
Yasmin Hamad +15 more
doaj +1 more source
Microdosimetric concepts relevant to HZE-particles [PDF]
The biological effectiveness of HZE-particles i s determined by the extreme microscopic concentrations of energy transfer in the vicinity of the particle tracks. The concept of linear energy transfer fails to describe this situation adequately.
Burke, W. R., Kellerer, Albrecht M.
core +1 more source
MRI-based gel dosimeters are attractive systems for the evaluation of complex dose distributions in radiotherapy. In particular, the nanocomposite Fricke gel dosimeter is one among a few dosimeters capable of accurately evaluating the dose distribution ...
Shinya Mizukami +9 more
doaj +1 more source
Despite continuous improvements in treatment of glioblastoma, tumor recurrence and therapy resistance still occur in a high proportion of patients. One underlying reason for this radioresistance might be the presence of glioblastoma cancer stem cells ...
P. Lesueur +8 more
semanticscholar +1 more source

