Results 181 to 190 of about 809,909 (347)
An all‐in‐fiber broadband polarization photodetector is demonstrated by integrating a PdSe2/2H‐MoTe2 van der Waals heterostructure onto a fiber endface. The device exhibits broadband response spanning 532 nm to 1630 nm, a fast response time of 59 µs, and a polarization ratio of 1.99. This work demonstrates a promising hardware strategy for polarization
Zexing Zheng +11 more
wiley +1 more source
Development of Nanoflare Nanosensors for Monitoring Cellular Insulin mRNA in Beta Cells and Islets
This study presents the design and application of In2‐NF probes for detecting insulin mRNA in beta cells and islets. Using spherical nucleic acid‐coated gold nanoparticles, the probes offer strong fluorescent signals upon hybridization. Their performance is validated across 2D and 3D cultures and rat islets, demonstrating sensitive, real‐time mRNA ...
Yana Hu +7 more
wiley +1 more source
Cellular senescence in cancer : from mechanism paradoxes to precision therapeutics
202511 bcchVersion of RecordRGCOthersThis study is supported by the NSFC-RGC Joint Research Scheme (N_CUHK448/23), National Natural Science Foundation of China (NSFC) (2022, No.
Feng, T +12 more
core +1 more source
This study presents a new biodegradable coating for titanium implants using a natural antimicrobial peptide, caerin 1.9. Applied via solvent casting, the coating offers sustained antibacterial protection and promotes healing. Tested on 3D‐printed porous titanium scaffolds, it effectively prevented infection—including against resistant bacteria—while ...
Hejie Li +7 more
wiley +1 more source
Chemically Doped Conductive Polymers for Wearable Health Monitoring
Among conductive polymers, poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS), polyaniline (PANI), and polypyrrole (PPy) are the most studied and applied. Chemical doping significantly boosts intrinsic conductivity and mechanical robustness.
Mengdi Zuo +5 more
wiley +1 more source
A 2×2 multiplexed GaAsSb nanowire photodetector array integrated with L‐shaped metasurfaces is developed for miniaturized infrared polarimetry. Leveraging non‐radiating anapole states that facilitate near‐field enhancement, the device demonstrates strong polarization selectivity at 835 nm.
Longsibo Huang +14 more
wiley +1 more source
TRIZ Inventive Solution in Solving Water Pipeline Leakage Using Accelerometer Sensor
To a developing country, sustaining a consistent water supply for industrial and domestic usages is a great challenge. In Malaysia, this can be demonstrated by the alarming rate of the Non-Revenue Water (NRW), which is >30% and this is greater than ...
Usman, Sahnius; Electrical Dept, PPD SPACE, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100, Kuala Lumpur, Malaysia +3 more
core